Blown-In Insulation Calculator

Plan loose-fill attic insulation using the selected product's bag coverage row. Compare current and target R-values, round an order to whole bags, or find coverage from bags already available.

Change any input to update the calculation. Unit changes preserve the physical quantity.

CALCULATION SETUP

Inputs

Effective existing layer only. Use 0 if uncertain; R-values are not insulation depths.

%

Your local currency; no product price is assumed.

Calculated locally in your browser. No sign-up or input upload.

YOUR CALCULATION

Results

Whole bags to order

16

Coverage / net project area

100 m²1,076.391 ft²

Required additional R-value

30 h·ft²·°F/BTU5.283 m²·K/W

Selected product-row R-value

30 h·ft²·°F/BTU5.283 m²·K/W

Estimated total layer R-value

30 h·ft²·°F/BTU5.283 m²·K/W

Added installed depth

281.94 mm11.1 in

Added settled depth

281.94 mm11.1 in

Product coverage per bag

6.781 m²72.993 ft²

Bag material cost

0 local currency
Installed 281.94 mmSettled 281.94 mmUse the selected product coverage chart
Installed and settled loose-fill insulation layers · schematic, not to scale

Calculation breakdown

Coverage row
Added label R 30 (US) · 72.9927 ft²/bag
Order method
Both manufacturer minimum bag density and maximum coverage are respected; whole bags round upward.

Assumptions & checks

Confirm the current bag label before ordering. The named JM attic chart is a reference snapshot; other products, cavity applications and installation methods use different charts.

Existing-plus-added R assumes continuous compatible layers. Moisture, air leakage, bridging, ventilation, clearances and fire requirements need separate assessment.

Formula

No universal R-per-inch or bags-per-area constant is used. A coverage row must meet the required additional R-value; between reference rows the next higher row is selected without interpolation.

Radd = max(0, Rtarget − Rexisting); bags = ceil[area × (1 + allowance/100) / label coverage]; coverage = available bags × label coverage / (1 + allowance/100)

Worked example

Using the default values shown in the calculator, the same formula gives the following result. This is a quick sanity check for the calculation, not a design recommendation.

Inputs

Coverage data
JM attic reference
Net area to insulate
100 m²
Assessed existing R-value
0 h·ft²·°F/BTU
Target total R-value
30 h·ft²·°F/BTU
Order allowance
5 %
Price per bag (optional)
0

Result

Whole bags to order
16
Coverage / net project area
100 m²
Required additional R-value
30 h·ft²·°F/BTU
Selected product-row R-value
30 h·ft²·°F/BTU
Estimated total layer R-value
30 h·ft²·°F/BTU
Added installed depth
281.94 mm
Added settled depth
281.94 mm
Product coverage per bag
6.781 m²
Bag material cost
0 local currency

Related calculators

Continue your workflow with a related calculation.

View all HVAC & Energy calculators

Frequently asked questions

Can I use any insulation product with the reference chart?

No. Use the current coverage chart for the exact product and application, or select manual label data. Fiberglass, cellulose and cavity-fill coverage are not interchangeable.

How is an in-between R target handled?

The named reference chart selects the next higher listed additional R-value. Manual data must already meet the required added R. No invented linear interpolation of bag coverage is used.

Is this a building-code insulation recommendation?

No. The target R-value is your input. Climate-zone requirements, installation clearances and assembly performance require separate project-specific checks.

Reference data & method sources

Reference tables

Climate Pro attic reference rows

Reference snapshot. Bag count honors both minimum bag density and maximum coverage. Verify the current product label.

Climate Pro attic reference rows
R (US)Installed inSettled inMin bags/1000 ft²Max ft²/bag
114.34.34.8209
13555.7176
197.27.28.4118
228.38.39.9101
269.79.711.885
3011.111.113.773
3813.813.817.756
4415.715.720.848
4917.317.323.543
6020.720.729.534