Step 1
Assess the heating envelope
Sum whole-assembly transmission and sensible outdoor-air loss with repeatable surfaces.
Open Heat LossCalculator cluster
Estimate heating loss, screen mini-split capacity, compare duct airflow and friction, plan loose-fill insulation and model heat-pump running cost.
11 calculators in this cluster
Start with envelope and outdoor-air assumptions before comparing equipment or energy costs. Heating loss, preliminary room cooling and annual useful energy represent different quantities and should not be substituted for each other.
These planning tools expose units, scenarios and model limits. Product-label insulation coverage and manufacturer equipment performance remain separate from a certified building or HVAC design.
Step 1
Sum whole-assembly transmission and sensible outdoor-air loss with repeatable surfaces.
Open Heat LossStep 2
Use a cooling screen or known design loads, then verify actual manufacturer output.
Open Mini-Split SizeStep 3
Compare round and rectangular duct velocity, friction and reverse airflow.
Open Duct SizeStep 4
Use verified COP/SCOP, useful heat and your own electricity tariff.
Open Heat Pump Running CostStep 5
Use the exact product's coverage row to estimate whole bags and layer depth.
Open Blown-In InsulationChoose the variable you know and the quantity you need to solve. Each tool shows its formula, default worked example, and nearby calculations.
Calculate blown-in insulation bags, installed and settled depth, coverage and cost from a manufacturer label, with metric and imperial measurements.
Estimate room or building heating loss from repeatable surface areas, U- or R-values, outdoor air changes and design temperatures in metric or imperial units.
Screen mini-split cooling capacity from room area and stated adjustments, or compare known heating and cooling loads with nominal BTU sizes.
Size round or rectangular ducts by airflow, velocity or straight-duct friction rate; reverse known dimensions to CFM with editable air properties.
Estimate heat-pump kWh, annual and average monthly running cost from heat demand or runtime, editable COP/SCOP, tariff and auxiliary electricity.
Relate room dimensions and airflow to nominal air changes per hour. SI/US units, clear methods and related references.
Estimate straight-duct insulation wrap area, allowance and insulation volume. SI/US units, clear methods and related references.
Build a homogeneous layer stack to solve R-value, U-value and interface temperatures. SI/US units, clear methods and related references.
Calculate sensible and latent cooling from an entered moist-air process or reverse airflow. SI/US units, clear methods and related references.
Estimate seasonal space-heating energy from a constant UA and heating degree days. SI/US units, clear methods and related references.
Convert same-condition COP and EER or calculate efficiency from measured powers. SI/US units, clear methods and related references.
Size round or rectangular ducts from CFM by velocity or straight-run friction. Check known inside dimensions and the airflow basis.
Plan the job →ENGINEERING WORKFLOW · 3 STEPSBuild an envelope and outdoor-air heat-loss estimate, compare a heat-pump capacity basis, then separate peak kW from annual kWh and running cost.
Plan the job →