Home / References / HVAC & Insulation VALICALC · TECHNICAL REFERENCE
Humidity Ratio & Dew Point Reference Look up humidity ratio, dew point and moist-air enthalpy for selected dry-bulb/RH pairs at 1 atm. Keep psychrometric conditions visible in HVAC planning.
SCENARIO MATRIX Metric Imperial
Search designation or dimension Search within the verified subset. Numeric sizes match complete designations; a nearby size is a candidate, not an exact match.
Dry-bulb °CAll dry-bulb °c 10 15 20 25 30 35 RH %All rh % 30 50 70 90
SELECTED REFERENCE
10 °C / 30% RH
Humidity ratio 2.279139 g/kg dry air
Dew-point temperature -6.01 °C
Moist-air enthalpy 15.798 kJ/kg dry air All fields & cell provenance
Dry-bulb temperature 10 °C
Relative humidity 30 % Copy result Add to comparison Copy share link
v1.3.0 · verified 2026-10-07
Scope of this lookup 24 pinned humid-air points: 10–35 °C and 30/50/70/90% RH, at 101325 Pa. No interpolation, outdoor design data or cooling-load estimate.
Before using these values Specific humidity and humidity ratio differ in mass basis. These points do not establish condensation safety, ventilation requirements or equipment latent capacity.
Sort byAir condition Humidity ratio Dew-point temperature Moist-air enthalpy Dry-bulb temperature Relative humidity Order: ascending
Humidity Ratio & Dew Point Reference, metric display Air condition Humidity ratio Dew-point temperature Moist-air enthalpy Actions 10 °C / 30% RH 2.279139 g/kg dry air -6.01 °C 15.798 kJ/kg dry air View Compare Copy row
10 °C / 50% RH 3.807867 g/kg dry air 0.064 °C 19.648 kJ/kg dry air View Compare Copy row
10 °C / 70% RH 5.344102 g/kg dry air 4.788 °C 23.517 kJ/kg dry air View Compare Copy row
10 °C / 90% RH 6.887898 g/kg dry air 8.437 °C 27.404 kJ/kg dry air View Compare Copy row
15 °C / 30% RH 3.169977 g/kg dry air -2.14 °C 23.101 kJ/kg dry air View Compare Copy row
15 °C / 50% RH 5.301308 g/kg dry air 4.674 °C 28.489 kJ/kg dry air View Compare Copy row
15 °C / 70% RH 7.447222 g/kg dry air 9.58 °C 33.912 kJ/kg dry air View Compare Copy row
15 °C / 90% RH 9.60787 g/kg dry air 13.375 °C 39.372 kJ/kg dry air View Compare Copy row
20 °C / 30% RH 4.355786 g/kg dry air 1.917 °C 31.17 kJ/kg dry air View Compare Copy row
20 °C / 50% RH 7.293698 g/kg dry air 9.274 °C 38.623 kJ/kg dry air View Compare Copy row
20 °C / 70% RH 10.259302 g/kg dry air 14.368 °C 46.145 kJ/kg dry air View Compare Copy row
20 °C / 90% RH 13.252993 g/kg dry air 18.311 °C 53.737 kJ/kg dry air View Compare Copy row
25 °C / 30% RH 5.917667 g/kg dry air 6.242 °C 40.219 kJ/kg dry air View Compare Copy row
25 °C / 50% RH 9.925739 g/kg dry air 13.867 °C 50.423 kJ/kg dry air View Compare Copy row
25 °C / 70% RH 13.985313 g/kg dry air 19.152 °C 60.757 kJ/kg dry air View Compare Copy row
25 °C / 90% RH 18.097386 g/kg dry air 23.245 °C 71.222 kJ/kg dry air View Compare Copy row
30 °C / 30% RH 7.955134 g/kg dry air 10.553 °C 50.513 kJ/kg dry air View Compare Copy row
30 °C / 50% RH 13.372587 g/kg dry air 18.451 °C 64.356 kJ/kg dry air View Compare Copy row
30 °C / 70% RH 18.884033 g/kg dry air 23.931 °C 78.435 kJ/kg dry air View Compare Copy row
30 °C / 90% RH 24.491941 g/kg dry air 28.178 °C 92.757 kJ/kg dry air View Compare Copy row
10 °C / 30% RH
Humidity ratio 2.279139 g/kg dry air
Dew-point temperature -6.01 °C
Moist-air enthalpy 15.798 kJ/kg dry air More dimensions
Dry-bulb temperature 10 °C
Relative humidity 30 % View Compare Copy row
10 °C / 50% RH
Humidity ratio 3.807867 g/kg dry air
Dew-point temperature 0.064 °C
Moist-air enthalpy 19.648 kJ/kg dry air More dimensions
Dry-bulb temperature 10 °C
Relative humidity 50 % View Compare Copy row
10 °C / 70% RH
Humidity ratio 5.344102 g/kg dry air
Dew-point temperature 4.788 °C
Moist-air enthalpy 23.517 kJ/kg dry air More dimensions
Dry-bulb temperature 10 °C
Relative humidity 70 % View Compare Copy row
10 °C / 90% RH
Humidity ratio 6.887898 g/kg dry air
Dew-point temperature 8.437 °C
Moist-air enthalpy 27.404 kJ/kg dry air More dimensions
Dry-bulb temperature 10 °C
Relative humidity 90 % View Compare Copy row
15 °C / 30% RH
Humidity ratio 3.169977 g/kg dry air
Dew-point temperature -2.14 °C
Moist-air enthalpy 23.101 kJ/kg dry air More dimensions
Dry-bulb temperature 15 °C
Relative humidity 30 % View Compare Copy row
15 °C / 50% RH
Humidity ratio 5.301308 g/kg dry air
Dew-point temperature 4.674 °C
Moist-air enthalpy 28.489 kJ/kg dry air More dimensions
Dry-bulb temperature 15 °C
Relative humidity 50 % View Compare Copy row
15 °C / 70% RH
Humidity ratio 7.447222 g/kg dry air
Dew-point temperature 9.58 °C
Moist-air enthalpy 33.912 kJ/kg dry air More dimensions
Dry-bulb temperature 15 °C
Relative humidity 70 % View Compare Copy row
15 °C / 90% RH
Humidity ratio 9.60787 g/kg dry air
Dew-point temperature 13.375 °C
Moist-air enthalpy 39.372 kJ/kg dry air More dimensions
Dry-bulb temperature 15 °C
Relative humidity 90 % View Compare Copy row
20 °C / 30% RH
Humidity ratio 4.355786 g/kg dry air
Dew-point temperature 1.917 °C
Moist-air enthalpy 31.17 kJ/kg dry air More dimensions
Dry-bulb temperature 20 °C
Relative humidity 30 % View Compare Copy row
20 °C / 50% RH
Humidity ratio 7.293698 g/kg dry air
Dew-point temperature 9.274 °C
Moist-air enthalpy 38.623 kJ/kg dry air More dimensions
Dry-bulb temperature 20 °C
Relative humidity 50 % View Compare Copy row
20 °C / 70% RH
Humidity ratio 10.259302 g/kg dry air
Dew-point temperature 14.368 °C
Moist-air enthalpy 46.145 kJ/kg dry air More dimensions
Dry-bulb temperature 20 °C
Relative humidity 70 % View Compare Copy row
20 °C / 90% RH
Humidity ratio 13.252993 g/kg dry air
Dew-point temperature 18.311 °C
Moist-air enthalpy 53.737 kJ/kg dry air More dimensions
Dry-bulb temperature 20 °C
Relative humidity 90 % View Compare Copy row
25 °C / 30% RH
Humidity ratio 5.917667 g/kg dry air
Dew-point temperature 6.242 °C
Moist-air enthalpy 40.219 kJ/kg dry air More dimensions
Dry-bulb temperature 25 °C
Relative humidity 30 % View Compare Copy row
25 °C / 50% RH
Humidity ratio 9.925739 g/kg dry air
Dew-point temperature 13.867 °C
Moist-air enthalpy 50.423 kJ/kg dry air More dimensions
Dry-bulb temperature 25 °C
Relative humidity 50 % View Compare Copy row
25 °C / 70% RH
Humidity ratio 13.985313 g/kg dry air
Dew-point temperature 19.152 °C
Moist-air enthalpy 60.757 kJ/kg dry air More dimensions
Dry-bulb temperature 25 °C
Relative humidity 70 % View Compare Copy row
25 °C / 90% RH
Humidity ratio 18.097386 g/kg dry air
Dew-point temperature 23.245 °C
Moist-air enthalpy 71.222 kJ/kg dry air More dimensions
Dry-bulb temperature 25 °C
Relative humidity 90 % View Compare Copy row
30 °C / 30% RH
Humidity ratio 7.955134 g/kg dry air
Dew-point temperature 10.553 °C
Moist-air enthalpy 50.513 kJ/kg dry air More dimensions
Dry-bulb temperature 30 °C
Relative humidity 30 % View Compare Copy row
30 °C / 50% RH
Humidity ratio 13.372587 g/kg dry air
Dew-point temperature 18.451 °C
Moist-air enthalpy 64.356 kJ/kg dry air More dimensions
Dry-bulb temperature 30 °C
Relative humidity 50 % View Compare Copy row
30 °C / 70% RH
Humidity ratio 18.884033 g/kg dry air
Dew-point temperature 23.931 °C
Moist-air enthalpy 78.435 kJ/kg dry air More dimensions
Dry-bulb temperature 30 °C
Relative humidity 70 % View Compare Copy row
30 °C / 90% RH
Humidity ratio 24.491941 g/kg dry air
Dew-point temperature 28.178 °C
Moist-air enthalpy 92.757 kJ/kg dry air More dimensions
Dry-bulb temperature 30 °C
Relative humidity 90 % View Compare Copy row
Show next 4 rows How to use this data Generate HAPropsSI W (kg water/kg dry air), D (dew-point K), H (J/kg dry air). Display W×1000, D−273.15 and H/1000. Preserve temperature/RH/pressure conditions.
CHECK THE METHOD
Worked example At 25 °C and 50% RH, dew point is about 13.9 °C. Humidity ratio is on dry-air mass; confirm actual pressure and measured humidity before using it.
Continue the reference workflow Common lookup questions What should I confirm before using this lookup? Specific humidity and humidity ratio differ in mass basis. These points do not establish condensation safety, ventilation requirements or equipment latent capacity.
TRACEABLE DATA
Sources, scope & verification Dataset v1.3.0 Last verified: 2026-10-07
24 pinned humid-air points: 10–35 °C and 30/50/70/90% RH, at 101325 Pa. No interpolation, outdoor design data or cooling-load estimate.
Values are curated product facts or generated scenarios. Paid standards, complete catalogs and source diagrams are not reproduced. A verification date applies to this documented subset.
Type C · CoolProp contributors · CoolProp 7.1.0; pinned JSON, not current online model version
Our selected generated model outputs. MIT attribution preserved in third-party-licenses/CoolProp-MIT.txt.
Full provenance & artifact record
Source checked 2026-10-07
Use basis open-license
Model revision 2a1c5d7231011ed1c20067b8528150398d12c841
Artifact SHA-256 No retained source artifact hash; see the stated source and verification record.