VALICALC · TECHNICAL REFERENCE

Humidity Ratio & Dew Point Reference

Look up humidity ratio, dew point and moist-air enthalpy for selected dry-bulb/RH pairs at 1 atm. Keep psychrometric conditions visible in HVAC planning.

SCENARIO MATRIX

Search within the verified subset. Numeric sizes match complete designations; a nearby size is a candidate, not an exact match.

SELECTED REFERENCE

10 °C / 30% RH

Humidity ratio
2.279139 g/kg dry air
Dew-point temperature
-6.01 °C
Moist-air enthalpy
15.798 kJ/kg dry air
All fields & cell provenance
Dry-bulb temperature
10 °C
Relative humidity
30 %

v1.3.0 · verified 2026-10-07

10 °C / 30% RH2.279139 g/kg dry airBack to answer ↑

Explore the verified data

24 matching rows · 24 in this subset

Humidity Ratio & Dew Point Reference, metric display
Air conditionHumidity ratioDew-point temperatureMoist-air enthalpyActions
10 °C / 30% RH2.279139 g/kg dry air-6.01 °C15.798 kJ/kg dry air
10 °C / 50% RH3.807867 g/kg dry air0.064 °C19.648 kJ/kg dry air
10 °C / 70% RH5.344102 g/kg dry air4.788 °C23.517 kJ/kg dry air
10 °C / 90% RH6.887898 g/kg dry air8.437 °C27.404 kJ/kg dry air
15 °C / 30% RH3.169977 g/kg dry air-2.14 °C23.101 kJ/kg dry air
15 °C / 50% RH5.301308 g/kg dry air4.674 °C28.489 kJ/kg dry air
15 °C / 70% RH7.447222 g/kg dry air9.58 °C33.912 kJ/kg dry air
15 °C / 90% RH9.60787 g/kg dry air13.375 °C39.372 kJ/kg dry air
20 °C / 30% RH4.355786 g/kg dry air1.917 °C31.17 kJ/kg dry air
20 °C / 50% RH7.293698 g/kg dry air9.274 °C38.623 kJ/kg dry air
20 °C / 70% RH10.259302 g/kg dry air14.368 °C46.145 kJ/kg dry air
20 °C / 90% RH13.252993 g/kg dry air18.311 °C53.737 kJ/kg dry air
25 °C / 30% RH5.917667 g/kg dry air6.242 °C40.219 kJ/kg dry air
25 °C / 50% RH9.925739 g/kg dry air13.867 °C50.423 kJ/kg dry air
25 °C / 70% RH13.985313 g/kg dry air19.152 °C60.757 kJ/kg dry air
25 °C / 90% RH18.097386 g/kg dry air23.245 °C71.222 kJ/kg dry air
30 °C / 30% RH7.955134 g/kg dry air10.553 °C50.513 kJ/kg dry air
30 °C / 50% RH13.372587 g/kg dry air18.451 °C64.356 kJ/kg dry air
30 °C / 70% RH18.884033 g/kg dry air23.931 °C78.435 kJ/kg dry air
30 °C / 90% RH24.491941 g/kg dry air28.178 °C92.757 kJ/kg dry air

10 °C / 30% RH

Humidity ratio
2.279139 g/kg dry air
Dew-point temperature
-6.01 °C
Moist-air enthalpy
15.798 kJ/kg dry air
More dimensions
Dry-bulb temperature
10 °C
Relative humidity
30 %

10 °C / 50% RH

Humidity ratio
3.807867 g/kg dry air
Dew-point temperature
0.064 °C
Moist-air enthalpy
19.648 kJ/kg dry air
More dimensions
Dry-bulb temperature
10 °C
Relative humidity
50 %

10 °C / 70% RH

Humidity ratio
5.344102 g/kg dry air
Dew-point temperature
4.788 °C
Moist-air enthalpy
23.517 kJ/kg dry air
More dimensions
Dry-bulb temperature
10 °C
Relative humidity
70 %

10 °C / 90% RH

Humidity ratio
6.887898 g/kg dry air
Dew-point temperature
8.437 °C
Moist-air enthalpy
27.404 kJ/kg dry air
More dimensions
Dry-bulb temperature
10 °C
Relative humidity
90 %

15 °C / 30% RH

Humidity ratio
3.169977 g/kg dry air
Dew-point temperature
-2.14 °C
Moist-air enthalpy
23.101 kJ/kg dry air
More dimensions
Dry-bulb temperature
15 °C
Relative humidity
30 %

15 °C / 50% RH

Humidity ratio
5.301308 g/kg dry air
Dew-point temperature
4.674 °C
Moist-air enthalpy
28.489 kJ/kg dry air
More dimensions
Dry-bulb temperature
15 °C
Relative humidity
50 %

15 °C / 70% RH

Humidity ratio
7.447222 g/kg dry air
Dew-point temperature
9.58 °C
Moist-air enthalpy
33.912 kJ/kg dry air
More dimensions
Dry-bulb temperature
15 °C
Relative humidity
70 %

15 °C / 90% RH

Humidity ratio
9.60787 g/kg dry air
Dew-point temperature
13.375 °C
Moist-air enthalpy
39.372 kJ/kg dry air
More dimensions
Dry-bulb temperature
15 °C
Relative humidity
90 %

20 °C / 30% RH

Humidity ratio
4.355786 g/kg dry air
Dew-point temperature
1.917 °C
Moist-air enthalpy
31.17 kJ/kg dry air
More dimensions
Dry-bulb temperature
20 °C
Relative humidity
30 %

20 °C / 50% RH

Humidity ratio
7.293698 g/kg dry air
Dew-point temperature
9.274 °C
Moist-air enthalpy
38.623 kJ/kg dry air
More dimensions
Dry-bulb temperature
20 °C
Relative humidity
50 %

20 °C / 70% RH

Humidity ratio
10.259302 g/kg dry air
Dew-point temperature
14.368 °C
Moist-air enthalpy
46.145 kJ/kg dry air
More dimensions
Dry-bulb temperature
20 °C
Relative humidity
70 %

20 °C / 90% RH

Humidity ratio
13.252993 g/kg dry air
Dew-point temperature
18.311 °C
Moist-air enthalpy
53.737 kJ/kg dry air
More dimensions
Dry-bulb temperature
20 °C
Relative humidity
90 %

25 °C / 30% RH

Humidity ratio
5.917667 g/kg dry air
Dew-point temperature
6.242 °C
Moist-air enthalpy
40.219 kJ/kg dry air
More dimensions
Dry-bulb temperature
25 °C
Relative humidity
30 %

25 °C / 50% RH

Humidity ratio
9.925739 g/kg dry air
Dew-point temperature
13.867 °C
Moist-air enthalpy
50.423 kJ/kg dry air
More dimensions
Dry-bulb temperature
25 °C
Relative humidity
50 %

25 °C / 70% RH

Humidity ratio
13.985313 g/kg dry air
Dew-point temperature
19.152 °C
Moist-air enthalpy
60.757 kJ/kg dry air
More dimensions
Dry-bulb temperature
25 °C
Relative humidity
70 %

25 °C / 90% RH

Humidity ratio
18.097386 g/kg dry air
Dew-point temperature
23.245 °C
Moist-air enthalpy
71.222 kJ/kg dry air
More dimensions
Dry-bulb temperature
25 °C
Relative humidity
90 %

30 °C / 30% RH

Humidity ratio
7.955134 g/kg dry air
Dew-point temperature
10.553 °C
Moist-air enthalpy
50.513 kJ/kg dry air
More dimensions
Dry-bulb temperature
30 °C
Relative humidity
30 %

30 °C / 50% RH

Humidity ratio
13.372587 g/kg dry air
Dew-point temperature
18.451 °C
Moist-air enthalpy
64.356 kJ/kg dry air
More dimensions
Dry-bulb temperature
30 °C
Relative humidity
50 %

30 °C / 70% RH

Humidity ratio
18.884033 g/kg dry air
Dew-point temperature
23.931 °C
Moist-air enthalpy
78.435 kJ/kg dry air
More dimensions
Dry-bulb temperature
30 °C
Relative humidity
70 %

30 °C / 90% RH

Humidity ratio
24.491941 g/kg dry air
Dew-point temperature
28.178 °C
Moist-air enthalpy
92.757 kJ/kg dry air
More dimensions
Dry-bulb temperature
30 °C
Relative humidity
90 %

How to use this data

Generate HAPropsSI W (kg water/kg dry air), D (dew-point K), H (J/kg dry air). Display W×1000, D−273.15 and H/1000. Preserve temperature/RH/pressure conditions.

    CHECK THE METHOD

    Worked example

    At 25 °C and 50% RH, dew point is about 13.9 °C. Humidity ratio is on dry-air mass; confirm actual pressure and measured humidity before using it.

    Common lookup questions

    What should I confirm before using this lookup?

    Specific humidity and humidity ratio differ in mass basis. These points do not establish condensation safety, ventilation requirements or equipment latent capacity.

    TRACEABLE DATA

    Sources, scope & verification

    Dataset v1.3.0
    Last verified:

    24 pinned humid-air points: 10–35 °C and 30/50/70/90% RH, at 101325 Pa. No interpolation, outdoor design data or cooling-load estimate.

    Values are curated product facts or generated scenarios. Paid standards, complete catalogs and source diagrams are not reproduced. A verification date applies to this documented subset.

    Generated dry/humid air thermophysical points ↗

    Type C · CoolProp contributors · CoolProp 7.1.0; pinned JSON, not current online model version

    Our selected generated model outputs. MIT attribution preserved in third-party-licenses/CoolProp-MIT.txt.

    Full provenance & artifact record
    Source checked
    2026-10-07
    Use basis
    open-license
    License
    MIT
    Model revision
    2a1c5d7231011ed1c20067b8528150398d12c841
    Artifact SHA-256
    No retained source artifact hash; see the stated source and verification record.

    VALICALC · PRIVACY