Home / References / Pipe & Fluid VALICALC · TECHNICAL REFERENCE
CPVC CTS Pipe Size Chart Look up selected Charlotte FlowGuard Gold CTS SDR11 pipe OD, minimum wall and calculated bore. Distinguish CTS CPVC from PVC or steel nominal sizes.
LOOK UP & COMPARE Metric Imperial
Search designation or dimension Search within the verified subset. Numeric sizes match complete designations; a nearby size is a candidate, not an exact match.
SELECTED REFERENCE
0.5 in FlowGuard Gold CTS SDR11
Calculated nominal bore 12.421 mm
Nominal / average OD 15.875 mm
Source wall thickness 1.727 mm All fields & cell provenance
Product family FlowGuard Gold CTS SDR11
Nominal inch designation 0.5
Calculated bore area 121.164 mm² Copy result Add to comparison Copy share link
v1.3.0 · verified 2026-10-07
Scope of this lookup Six selected named CPVC CTS SDR11 dimensional examples from CTS-PIPE-124. Average OD/minimum wall; derived bore is not a guaranteed measured ID.
Before using these values Never use or test this CPVC with compressed air/gas. Verify current product, service temperature, pressure and chemical compatibility; this is a dimensional lookup only.
Sort byProduct / tube designation Calculated nominal bore Nominal / average OD Source wall thickness Product family Nominal inch designation Calculated bore area Order: ascending
CPVC CTS Pipe Size Chart, metric display Product / tube designation Calculated nominal bore Nominal / average OD Source wall thickness Actions 0.5 in FlowGuard Gold CTS SDR11 12.421 mm 15.875 mm 1.727 mm View Compare Copy row
0.75 in FlowGuard Gold CTS SDR11 18.161 mm 22.225 mm 2.032 mm View Compare Copy row
1 in FlowGuard Gold CTS SDR11 23.393 mm 28.575 mm 2.591 mm View Compare Copy row
1.5 in FlowGuard Gold CTS SDR11 33.757 mm 41.275 mm 3.759 mm View Compare Copy row
1.25 in FlowGuard Gold CTS SDR11 28.575 mm 34.925 mm 3.175 mm View Compare Copy row
2 in FlowGuard Gold CTS SDR11 44.171 mm 53.975 mm 4.902 mm View Compare Copy row
0.5 in FlowGuard Gold CTS SDR11
Calculated nominal bore 12.421 mm
Nominal / average OD 15.875 mm
Source wall thickness 1.727 mm More dimensions
Product family FlowGuard Gold CTS SDR11
Nominal inch designation 0.5
Calculated bore area 121.164 mm² View Compare Copy row
0.75 in FlowGuard Gold CTS SDR11
Calculated nominal bore 18.161 mm
Nominal / average OD 22.225 mm
Source wall thickness 2.032 mm More dimensions
Product family FlowGuard Gold CTS SDR11
Nominal inch designation 0.75
Calculated bore area 259.042 mm² View Compare Copy row
1 in FlowGuard Gold CTS SDR11
Calculated nominal bore 23.393 mm
Nominal / average OD 28.575 mm
Source wall thickness 2.591 mm More dimensions
Product family FlowGuard Gold CTS SDR11
Nominal inch designation 1
Calculated bore area 429.81 mm² View Compare Copy row
1.5 in FlowGuard Gold CTS SDR11
Calculated nominal bore 33.757 mm
Nominal / average OD 41.275 mm
Source wall thickness 3.759 mm More dimensions
Product family FlowGuard Gold CTS SDR11
Nominal inch designation 1.5
Calculated bore area 894.968 mm² View Compare Copy row
1.25 in FlowGuard Gold CTS SDR11
Calculated nominal bore 28.575 mm
Nominal / average OD 34.925 mm
Source wall thickness 3.175 mm More dimensions
Product family FlowGuard Gold CTS SDR11
Nominal inch designation 1.25
Calculated bore area 641.302 mm² View Compare Copy row
2 in FlowGuard Gold CTS SDR11
Calculated nominal bore 44.171 mm
Nominal / average OD 53.975 mm
Source wall thickness 4.902 mm More dimensions
Product family FlowGuard Gold CTS SDR11
Nominal inch designation 2
Calculated bore area 1,532.345 mm² View Compare Copy row
How to use this data Use named source average OD and minimum wall. ID=OD−2minimum wall; convert inch facts exactly. CTS dimensions remain separate from IPS/PVC Schedule 40/80 dimensions.
CHECK THE METHOD
Worked example 1/2 in named CTS product: OD 0.625 in, minimum wall 0.068 in, calculated nominal bore 0.489 in = 12.4206 mm.
Continue the reference workflow Common lookup questions What should I confirm before using this lookup? Never use or test this CPVC with compressed air/gas. Verify current product, service temperature, pressure and chemical compatibility; this is a dimensional lookup only.
TRACEABLE DATA
Sources, scope & verification Dataset v1.3.0 Last verified: 2026-10-07
Six selected named CPVC CTS SDR11 dimensional examples from CTS-PIPE-124. Average OD/minimum wall; derived bore is not a guaranteed measured ID.
Values are curated product facts or generated scenarios. Paid standards, complete catalogs and source diagrams are not reproduced. A verification date applies to this documented subset.
Type C · Charlotte Pipe · CTS-PIPE-124 effective 2024-01-01, page 1
A bounded subset of named public product/service facts, paraphrased with conditions; catalog text, drawings and complete tables are not reproduced.
Full provenance & artifact record
Source checked 2026-10-07
Use basis bounded-product-facts
Artifact SHA-256 No retained source artifact hash; see the stated source and verification record.